Check voltage between mode door motor connector M127 terminal 3 and ground, between air mix door motor (LH) connector M128 terminal 3 and ground, between air mix door motor (RH) connector M129 terminal 3 and ground, and between intake door motor connector
M126 terminal 3 and ground.
Is the Inspection result normal?
YES >> GO TO 4
NO >> Replace harness or connector. 4.CHECK SIGNAL FOR MOTOR
Check voltage between mode door motor connector M127 terminal 1 and ground, between air mix door motor (LH) connector M128 terminal 1 and ground, between air mix door motor (RH) connector M129 terminal 1 and ground, and between intake door motor connector
M58 terminal 1 and ground.
Is the Inspection result normal?
YES >> GO TO 5
NO >> Replace harness or connector. 5.CHECK MOTOR GROUND CIRCUIT
Press ignition switch OFF.
Disconnect door motor connectors.
Check continuity between mode door motor connector M127 terminal 2 and ground, between air mix door motor (LH) connector M128 terminal 2 and ground, between air mix door motor (RH) connector M129 terminal 2 and ground, and between intake door motor connector M126 terminal 2 and ground.
Is the Inspection result normal?
YES >> GO TO 6
NO >> Replace harness or connector. 6.CHECK MOTOR OPERATION
Disconnect and reconnect the motor connectors and confirm the motor operation.
Is the Inspection result normal?
YES >> (Returns to normal operation.)
Motor connector contacts dirty or damaged NO >> (Does not operate normally.)
GO TO 7 7.CHECK MODE DOOR MOTOR AND AIR MIX DOOR MOTORS OPERATION
Disconnect the intake door motor connector.
Reconnect the mode door motor connector and air mix door motor connectors, confirm the mode door motor and air mix door motors operation. Is the Inspection result normal?
YES >> (Mode door motor and air mix door motors operate normally.)
GO TO 9 9.CHECK INTAKE DOOR MOTOR AND MODE DOOR MOTOR OPERATION
Disconnect air mix door motor connectors.
Reconnect mode door motor connector, confirm the intake door motor and mode door motor operation. Is the Inspection result normal?
YES >> (Intake door motor and mode door motor operate normally.)
Replace inoperative air mix door motor. Refer to See: Air Door\Service and Repair. NO >> (Intake door motor and mode door motor do not operate normally.)