The ignition signal from the ECM is sent to and amplified by the power transistor. The power transistor turns ON and OFF the ignition coil primary circuit. This ON/OFF operation induces the proper high voltage in the coil secondary circuit.
Check the continuity between condenser harness connector and ground.
Also check harness for short to power. Is the Inspection result normal?
YES >> GO TO 5.
NO >> Repair open circuit or short to power in harness or connectors. 5.CHECK CONDENSER
Refer to See: Component Inspection (Condenser)
Is the Inspection result normal?
YES >> GO TO 6.
NO >> Replace condenser. 6.CHECK IGNITION COIL POWER SUPPLY CIRCUIT-V
Check the voltage between ignition coil harness connector and ground.
Is the Inspection result normal?
YES >> GO TO 7.
NO >> Repair or replace harness or connectors. 7.CHECK IGNITION COIL GROUND CIRCUIT FOR OPEN AND SHORT